Menu
Menu
Your Cart

British Gypsum Gypframe 92 I 90 I Stud 6 m (pack of 10)

British Gypsum Gypframe 92 I 90 I Stud 6 m (pack of 10)
Price: £488.13 (£585.76 inc VAT)
3 or more £479.41 (£575.29 inc VAT)
4 or more £477.35 (£572.82 inc VAT)
5 or more £457.61 (£549.13 inc VAT)
  • Product Code: A1-811
  • Delivery Time: 2 - 3 working days
  • Brand: British Gypsum
  • (Tech. support: 01159456123)
  • Model: 92 I 90 'I' Stud - 6 m
  • Weight: 96.60kg
Our ratings on 08-11-2024:
Google My Business Reviews
4.8 out of 5
Show other lengths

British Gypsum Gypframe 92 I 90 'I' Stud 6 m (pack of 10)

Width: 92mm
Length: 6000mm
Weight: 96.6kg

British Gypsum Gypframe 92 I 90 6 m 'I' studs provide additional impact resistance due to the improved strength, unlike any other available Gypframe studs. They are usually used in systems with paramount board fixing strength, allowing increased partition height, but retaining the same partition width. Services can be easily routed through the partition due to the spaced structural apertures.

The studs are used in various systems, including:

  • FireWall provides up to 240 minutes of fire resistance, while requiring minimal wall thickness, especially designed to meet the requirements of insurance companies in the words of fire protection, why it is especially applicable to warehouses, plant rooms and data storages. Special care should be given to any insulation system installed in order of preventing it to anyhow affect the performance of the system, which also goes for any openings is the wall which are generally not required with the FireWall system. Finally, it is advisable that a damp proof membranes are installed if dealing with a new concrete screeded floor;
  • GypLyner IWL, providing fire protection and fire resistance, used for upgrading both thermal and sound performance of masonry walls, designed to correspond to BS 5234 standards. The system can increase the sound and thermal insulation of both new or existing walls, only if the elements are well fitted to the background, junctions properly sealed and water penetration and damp issues taken care of by applying recommended measures;
  • GypWall QUIET IWL is in compliance with the Robust details constructions, meaning that there is no pre-completed testing required, also designed to meet BS 5234 requirements, used to accommodate services between the twin stud frameworks;
  • GypWall STAGGERED has a wide application in both commercial and residential buildings such as hospitals, schools, offices, shops etc., all due to increased sound insulation properties at a minimal partition width, in conformity with the BS 5234 and providing up to 90 minutes of fire resistance. When installing, it is important that the linings are not separated by a bridge created from the fixtures and services;
  • ShaftWall is a lightweight system which can be installed in the early construction phase, especially applicable to areas with limited access, providing a fire-protective structure for the inner elements. It is designed to meet air pressure and deflection requirements, but also the boundary requirements prescribed by the applicable Approved Document B of the Building Regulations. The system can be found in stairwells, service ducts and risers and lift shafts, providing a protective enclosure.
APPLICATION

Gypframe 92 I 90 6 m 'I' studs are particularly applicable in systems with paramount board fixing strength.

CERTIFICATION

The product is in compliance with the:

  • British Standard BS 7364
  • European Standard EN 14195
  • American Standard ASTM C645
25mm Glasroc F Firecase
Guide Price
Brand: British Gypsum Model: 2000x1200mm - 2.40m2
Delivery Time: 1 - 2 days
25mm Glassroc F Firecase is a highly versatile, Class 0, non-combustible glass reinforced gypsum board. The non-combustibility of gypsum and the reinforcement of glass fibre combine to produce a strong and resilient product, which has resistance to sag and offers excellent fire protection. It consis..
Guide Price: £89.08
£106.90 inc VAT
Brand: British Gypsum Model: GAB3 - 459mm
Delivery Time: 2 - 4 days
British Gypsum Gypframe GAB3 Acoustic Brace is especially designed and engineered to be used in high performance applications where substantial acoustic insulation essential, such as cinemas and theatres, why it is an integral part of the GypWall AUDIO which is a system especiall..
£135.57
£162.68 inc VAT
6mm Glasroc F MultiBoard
Guide Price
Brand: British Gypsum Model: 2400x1200mm - 2.88.m2
Delivery Time: 2 - 3 working days
6mm Glasroc F MultiBoard is a highly versatile, Class 0, non-combustible glass reinforced gypsum board manufactured by a unique continuous process, developed and patented by British Gypsum. The non-combustibility of gypsum and the reinforcement of glass fibre combine to produce a strong and resilien..
Guide Price: £36.59
£43.91 inc VAT
Brand: British Gypsum Model: 148 EDC 80 - 3.6 m
Delivery Time: 3 - 5 days
British Gypsum Gypframe 148 EDC 80 Extra Deep Flange Floor & Ceiling Channel is used for securing wall studs in ceiling and floor junctions for partition heights over 4200mm up to 8000mm. The product is specially applicable to constructions where better impact resistance and ..
£42.23
£50.68 inc VAT
Brand: British Gypsum Model: G108 Retaining Clip
Delivery Time: 2 - 3 working days
British Gypsum Gypframe Shaftwall G108 Retaining Clip is a compatible accessory especially designed to be used for 92mm Gypframe I Studs, with the ShaftWall System, a lightweight system which can be installed in the early construction phase, especially applicable to areas wi..
£159.21
£191.05 inc VAT
Brand: British Gypsum Model: 1200x2400mm - 2.88m2
Delivery Time: 3 - 5 days
15mm Gyproc WallBoard Duplex is used for wall and ceiling linings where vapour control and plasterboard lining are required in one fixing operation. Gyproc WallBoard duplex consists of an aerated gypsum core encased in, and firmly bonded to, strong paper liners and backed with an additional metalise..
£19.50
£23.40 inc VAT

Rate this product

Please login or register to review
This product is listed in the following categories and systems (click to show).